SAPT presents the PowerXcel ENERGIX Series, a cutting-edge 3-Phase Online UPS featuring an IGBT-based rectifier, IGBT-based inverter, and a built-in isolation transformer.
Designed for industrial, commercial, and mission-critical applications, this UPS delivers high efficiency, superior power quality, and complete electrical isolation, ensuring uninterrupted and reliable performance.
Power factor affects electricity consumption by influencing the amount of current drawn from the grid. A low power factor increases current flow, leading to higher energy losses, overheating of equipment, and higher electricity bill
By improving power factor correction systems, energy losses can be minimized, electricity bills reduced, and overall power system efficiency enhanced.
| CAPACITY | kVA | 10 | 15 | 20 | 30 | 40 | 50 | 60 |
|---|---|---|---|---|---|---|---|---|
| kW | 8 | 12 | 16 | 24 | 32 | 40 | 48 | |
| TYPE | Low Frequency Isolation Transformer Based | |||||||
| INPUT | Phase | Three Phase (3P+N) | ||||||
| Input Voltage Range | 415V AC ± 25% | |||||||
| Input Frequency | 50HZ ± 5% | |||||||
| Power Factor | >0.95% | |||||||
| Input Ripple | < 5% | |||||||
| Soft Start | 0~100% 5 second | |||||||
| OUTPUT | Nominal Voltage | 380/400/415V AC, (3P+N) | ||||||
| Regulation | ±1% for Linear & Non-Linear Load | |||||||
| Output Frequency | 50HZ ± 0.5% | |||||||
| Crest Factor | > 3:1 | |||||||
| Power Factor | 0.8 | |||||||
| Output THD | Linear Load < 3%, Non-Linear Load < 5% | |||||||
| Efficiency | Up to >95% (Full Load) | |||||||
| BATTERY | DC Voltage | 360-384 VDC (selectable) | ||||||
| Number of Battery | 30-32 (Selectable) | |||||||
| Charging Current | 1-20 Amp (settable) - Expandable to 40Amp | |||||||
| BYPASS | Phase | Single Phase (3P+N) | ||||||
| Manual | Maintenance Bypass Switch Provided | |||||||
| Static | No Break (Optional) | |||||||
| PROTECTION | Input Protection | Input Voltage, Frequency Under/Over limit Protection | ||||||
| Output Protection | Over Current, Short-Circuit, Over/Under Voltage | |||||||
| Battery Protection | Over Charge, Over Discharge protection | |||||||
| Temperature Protection | Inverter Over Temperature Protection | |||||||
| GENERAL PARAMETERS | Working Environment | Temp: 10-550 C, Relative Humidity : 30-90% | ||||||
| Display | LCD + Physical Button | |||||||
| Alarm | Low Battery, Abnormal AC Input, UPS Failure, etc. | |||||||
| Noise (dB) | < 55 | |||||||
| Dimensions (L*W*H) | 690 X 386 X 719 | 689 X 387 X 756 | 850 X 412 X 1001 | 854 X 462 X 1261 | ||||
| Weight (kg) | 122 | 152 | 160 | 214 | 272 | 330 | 351 | |